Compression Machine |
SOP For Compression Machine
Standard Operating Procedure for compression machine or
rotary Compression Machine.
1.0 Purpose
The purpose of this
SOP is to establish a standard procedure for operating the compression machine.
2.0 Scope
This SOP will be applicable
for the compression machine in the compression area of the production
section.
3.0 Responsibility
3.1 Machine Operator
is responsible for operating the Compression Machine.
3.2 Production
Pharmacist is responsible for the implementation of this SOP.
3.3 HOP is responsible
to ensure the implementation of this SOP.
3.4 Quality Assurance
Officer monitors the compliance of this SOP.
4.0 Procedure
4.1 Production
Pharmacist will ensure that the compression machine and the area are properly cleaned.
4.2 Production
Pharmacist will ensure that the compression machine and Area is labeled with
Cleaned label status.
4.3 Before starting
the operation of a compression Machine ensure that the machine is installed
with tooling as mentioned in BMR or batch manufacturing record.
4.4 The production
Pharmacist should ensure that all the tooling is properly installed, meaning
punches are free to move in dies and dies are tightly screwed.
4.5 After ensuring
that hoppers and feed frames are installed correctly, award line clearance.
4.6 After production
line clearance, take line clearance from the QA officer.
4.6 After line
clearance, add powder or granules in the hoppers of the compression machine and
ensure that the pressure rollers and weight regulators are neutral.
4.7 Rotate the machine
manually to ensure proper filing of feed frame housings and dies.
4.8 Operate the
machine at jog speed, apply little pressure and adjust the weight of the tablet
according to BMR or batch manufacturing record.
4.9 When required
tablet weight is achieved apply more pressure to set hardness and thickness of
tablet according to the batch manufacturing record.
4.10 When required
tablet weight, hardness and thickness are achieved, turn on the tablet deduster
and metal detector & increase the speed or RPMs of the compression machine.
4.11 Adjust tablet
weight, hardness and thickness again if required.
4.12 Take samples for
in-process testing and after clearance of all the parameters compress the whole
batch.
4.13 After
compression, turn off the machine,affix to be cleaned label and record the
activity in the logbook.
5.0 Abbreviations
5.1 SOP: Standard
Operating Procedure
5.2 rpm: Rounds
per minute
5.3 BMR: Batch
Manufacturing Record
5.4 QA:
Quality Assurance
5.5 HOP: Head Of
Production
0 Comments